Skip to main content

Control system for scroll units
CIATrtc

CIATrtc control is an electronic module with microprocessor designed for the control and supervision of air-air units (especially for packaged systems). This control is implemented in the following CIAT ranges: ISPK and ISC/RSC.

Different terminal options (user / maintenance)
Multilingual
Numerous configurable features
BMS communication

This control enables unit integration with local supervision solutions: pCO Web (1 unit); BOSS mini (up to 50 units) and BOSS (up to 300 units), as well as with the remote solution.

One model available

Management of up to four refrigerant circuits, four scroll compressors and energy recovery systems

CIATrtc control is a specific management system for air-to-air and water-to-air units with scroll compressors

  • Main board for unit with scroll compressor
  • Safety pressure switches
  • Main board and software configured by CIAT
  • pGD1 CONTROL
    • Backlit, user-friendly screen
    • Screen sized for easy use and extended display of information
    • Multilingual
  • TCO (instead of PGD1)
    • Simple TCO user terminal
    • Without access to parameters
  • Control of cooling, heating, automatic, ventilation and dehumidification modes
  • Cut-in temperature control (proportional-integral control)
  • Management of DEGIPAC defrosting (air-to-air heat pumps) via outdoor pressure and temperature sensors (difference between the evaporating temperature and the outdoor temperature)
  • Control of the condensing temperature and evaporating temperature of the outdoor coil via pressure sensors
  • Supply and/or return airflow managament by EC plugfans
  • Active recovery management
  • Heat wheel exchanger management
  • Gas burner management
  • Ambient temperature sensor
  • Management of the electric heaters on the auxiliary hot water coil
  • Thermal, enthalpy or thermal-enthalpy free cooling
  • Smoke detection
  • Detection of dirty filters
  • Electrical energy meter
  • Refrigerant leak detector
  • Excellent EER and ESEER energy efficiency thanks to high-efficiency refrigerant and high-performance exchangers and compressors
  • Uses a non-ozone-depleting refrigerant
  • Very low sound level, no vibrations
  • Easy installation: small enough to fit against a wall
  • Unit tested in factory and delivered ready for use
  • Hydraulic connections located at top of the unit for quick installation regardless of the layout of the plant room
  • Electrical power supply without a neutral conductor: transformer provided for in cabinet
  • Easy maintenance: clearly labelled information and easily detachable panels provide access to all internal components
  • Versatile control, remote communication, output contacts, intuitive user-friendly interface
  • A solution that offers excellent comfort and energy savings, and is environmentally sustainable
  • Compatible with system management easy & smart CIATControl
  • Compatible with remote connectivity monitoring solution

One model available

Management of up to four refrigerant circuits, four scroll compressors and energy recovery systems

CIATrtc control is a specific management system for air-to-air and water-to-air units with scroll compressors

  • Main board for unit with scroll compressor
  • Safety pressure switches
  • Main board and software configured by CIAT
  • pGD1 CONTROL
    • Backlit, user-friendly screen
    • Screen sized for easy use and extended display of information
    • Multilingual
  • TCO (instead of PGD1)
    • Simple TCO user terminal
    • Without access to parameters
  • Control of cooling, heating, automatic, ventilation and dehumidification modes
  • Cut-in temperature control (proportional-integral control)
  • Management of DEGIPAC defrosting (air-to-air heat pumps) via outdoor pressure and temperature sensors (difference between the evaporating temperature and the outdoor temperature)
  • Control of the condensing temperature and evaporating temperature of the outdoor coil via pressure sensors
  • Supply and/or return airflow managament by EC plugfans
  • Active recovery management
  • Heat wheel exchanger management
  • Gas burner management
  • Ambient temperature sensor
  • Management of the electric heaters on the auxiliary hot water coil
  • Thermal, enthalpy or thermal-enthalpy free cooling
  • Smoke detection
  • Detection of dirty filters
  • Electrical energy meter
  • Refrigerant leak detector
  • Excellent EER and ESEER energy efficiency thanks to high-efficiency refrigerant and high-performance exchangers and compressors
  • Uses a non-ozone-depleting refrigerant
  • Very low sound level, no vibrations
  • Easy installation: small enough to fit against a wall
  • Unit tested in factory and delivered ready for use
  • Hydraulic connections located at top of the unit for quick installation regardless of the layout of the plant room
  • Electrical power supply without a neutral conductor: transformer provided for in cabinet
  • Easy maintenance: clearly labelled information and easily detachable panels provide access to all internal components
  • Versatile control, remote communication, output contacts, intuitive user-friendly interface
  • A solution that offers excellent comfort and energy savings, and is environmentally sustainable
  • Compatible with system management easy & smart CIATControl
  • Compatible with remote connectivity monitoring solution
Documents

Controls manual