Air flow rate control
FRESH AIR CONTROL
FRESH AIR CONTROL enables the fresh air flow rate introduced to be adapted according to the actual occupation and to control energy expenditure due to air renewal.
R+ pack with CO2 sensor for use in meeting rooms
R1 pack with occupancy sensor for use in offices
R+ package with CO2 sensor for meeting room application
R1 package with presence sensor for office application
These systems are intended for premises with a variable occupancy such as offices or meeting rooms.
They enable the fresh air flow rate introduced to be adapted according to the actual occupation and to control energy expenditure due to air renewal.
Introduce fresh air only if occupancy. The pack is composed of:
- R1E motorized damper with double flow rate calibrated to the fresh air controlled by a presence sensor, recessed in the ceiling:
- 1 minimum air flow rate, ensuring the sanitary integrity of the room
- 1 nominal air flow rate when occupied
Modulate your fresh air according to the occupancy rate of your meeting rooms.
The CO2 rate, which is representative of the number of people present in the room, modulates the fresh air flow rate introduced by through the R+E progressive damper, which has a self-calibrated minimum flow rate to ensure sanitary integrity of the room.
Save energy and optimize the air quality: since the treatment of fresh air accounts for up to 70% of the heating and cooling needs in office buildings, this adjustment in the flow of fresh air results in significant energy savings.
R+ package with CO2 sensor for meeting room application
R1 package with presence sensor for office application
These systems are intended for premises with a variable occupancy such as offices or meeting rooms.
They enable the fresh air flow rate introduced to be adapted according to the actual occupation and to control energy expenditure due to air renewal.
Introduce fresh air only if occupancy. The pack is composed of:
- R1E motorized damper with double flow rate calibrated to the fresh air controlled by a presence sensor, recessed in the ceiling:
- 1 minimum air flow rate, ensuring the sanitary integrity of the room
- 1 nominal air flow rate when occupied
Modulate your fresh air according to the occupancy rate of your meeting rooms.
The CO2 rate, which is representative of the number of people present in the room, modulates the fresh air flow rate introduced by through the R+E progressive damper, which has a self-calibrated minimum flow rate to ensure sanitary integrity of the room.
Save energy and optimize the air quality: since the treatment of fresh air accounts for up to 70% of the heating and cooling needs in office buildings, this adjustment in the flow of fresh air results in significant energy savings.